Tin Dioxide-Graphene Based Chemi-Device for NO2 Detection in the Sub ppm Range

tin dioxide
graphene
nanofibers
chemi-device
sensor
nitrogen
J. P. Santos , T. Polichetti, M. Aleixandre, E. Hontañón, I. Sayago, B. Alfano, M. L. Miglietta and G. Di Francia
Vol. 1 Eurosensors 2017, Proceedings 2017, 1(4), 442
http://dx.doi.org/10.3390/proceedings1040442

Chemical nanodevices based on tin dioxide, graphene and a mixture of both materials were developed and characterized for NO2 detection at low concentrations. The chemiresistors were prepared by both electrospinning and drop casting. The films morphologies were investigated by scanning electron microscopy (SEM). The devices response to sub-ppm NO2 concentrations was measured from room temperature up to 300 °C. An improvement in the performance in terms of sensitivity and response time, as well as higher responses at room temperature, was obtained when a mixture of these materials is used.

Acknowledgments

Authors want to thank Spanish Ministry of Economy and Competitiveness for supporting the project TEC2013-48147-C6.

NOySI
Acoustics and Non Destructive Evaluation (DAEND)
  • Environmental Acoustics (GAA)
  • G Carma: Materials Characterization by Non Destructive Evaluation
  • ULAB, Ultrasounds for Liquid Analysis and Bioengineering
Information and Communication Technologies (TIC)
  • Cybersecurity and Privacy Protection Research Group (GiCP)
  • Research group on Cryptology and Information Security (GiCSI)
    • Quantum Communications Laboratory (LCQE)
  • Multichannel Ultrasonic Signal Processing Group (MUSP)
Sensors and Ultrasonic Systems (DSSU)
  • Ultrasonic Systems and Technologies (USTG)
  • Nanosensors and Smart Systems (NoySi)
  • Ultrasonic Resonators for cavitation and micromanipulation (RESULT)
  • Advanced Sensor Technology (SENSAVAN)
  • Quantum Electronics (QE)
Laboratorios
  • Laboratorio de Acústica
  • Laboratorio de Metrología Ultrasónica Médica (LMUM)
  • Laboratorio de Comunicaciones Cuánticas
  • Laboratory for International Collaboration in Advanced Biophotonics Imaging

Instituto de Tecnologías Físicas y de la Información Leonardo Torres Quevedo  - ITEFI
C/ Serrano, 144. 28006 - Madrid • Tel.: (+34) 91 561 88 06  Contacto  •  Intranet
EDIFICIO PARCIALMENTE ACCESIBLE POR PERSONAS CON MOVILIDAD REDUCIDA